The RTM3 flowmeter with floating ball is used to adjust and measure the flow of a gas that is to be delivered to patients through the respiratory tract. The RTM3 should be connected to a source of pressured gas on the wall either using a direct probe or a rail mounting system. It must be fitted at its outleteither with a humidifier/nebulizer or with an outlet tubing nipple.

SPECIFTICATIONS:
Flowmeter with compensated pressure ensuring a perfect flowrate stability and accuracy. The scale works with the same pressure than the one of the network and is not sensitive to back-pressure.
Expanded scale providing higher reading accuracy for lower flowrates for 5 l/min and 15 l/min versions.
Type of “cartridge” knob, extremely reliable, easy-to-clean and ensuring an optimized adjustment. Perfect tightness of the knob thanks to its polyamide seat. We guarantee the closing of the knob during 5 years without any leakage.
Monoblock scale cover made of polycarbonate for a better sturdiness and a higher shock-resistance. No access to the scale by the patient.
A metallic sieve located at the inlet of the flowmeter protects the device against impurities of the gas network and thus ensures the protection of the patient. Filter porosity: 35 microns.
Body made of nickel-plated brass.
Unit serial number engraved on each flowmeter body for identification and traceability.

TM Catalogue RTM3

TM Catalogue RTM3

AVAILABLE VESIONS:
Gases :
O2, medical Air, CO2, Carbogen
Flowrates :
O2 and medical Air: 1.5 l/min (paediatric), 5 l/min, 15 l/min, 30 l/min
CO2: 12 l/min
Carbogen: 15 l/min

Flowmeters - DEBFLO / DEBPLUS

The flowmeters with pre-adjusted flowrates DEBFLO and DEBPLUS are used to set the flow of a gas that is to be delivered to patients through the respiratory tract. They should be connected to a source of pressured gas on the wall either using a direct probe or a rail mounting system. They must be fitted at the outlet either with a humidifier/nebulizer or with an outlet tubing nipple.

  • SPECIFTICATIONS:
    15 different flowrates available for each version.
    Great readability for a perfect readability of all the flowrates even from a distance.
    Built-in regulator (DEBPLUS) providing precise flow in case of non-stable gas network.
    Good grip of the control wheel.
    Flow control knob equipped with a ratchet mechanism avoiding accidental flowrate change.
    Presence of a gas flow between two positions ensuring the gas supply for the patient even if the device is accidentally positioned between two settings.
    Supplied with a stop system preventing the medical staff from switching from 0 to the maximum flow and conversely.
    Unit serial number engraved on each flowmeter body ensuring its identification and its traceability.
    Inlet pressure:
    DEBFLO: 4.5 bar +/- 0.5
    DEBPLUS: 2.8 to 8 bar
    DEBFLO without built-in regulator (grey body)
    DEBPLUS with built-in regulator (white body)

AVAILABLE VESIONS:
Gases: O2, medical Air
Flowrates: 5 l/min, 15 l/min
Single and twin version
Standards: AFNOR (French standard), BS (British standard), DIN (German standard), US OHMEDA (American standard), UNI (Italian standard), NORDIC (Scandinavian standard), CARBUROS METALICOS (Spanish standard), DISS (American standard), CZECH (Czech standard) and Korean/Japanese standard.
Contact us for other standard.

Flowmeters - DEBSON TM2

The DEBSON 2 flowmeter with pre-adjusted flows is used to set the flow of a gas that is to be delivered to patients through the respiratory tract. It should be connected to a source of pressured gas on the wall either using a direct probe or a rail mounting system. It must be fitted at its outlet either with a humidifier/nebulizer or with an outlet tubing nipple.

SPECIFTICATIONS
Flowmeter with pre-adjusted flowrates: accurate and stable flowrates.
It can be used in any orientation for a perfect adaptation to the medical needs especially for emergency.
Flow control knob equipped with a ratchet mechanism avoiding accidental flowrate change.
Presence of a gas flow between two positions ensuring the gas supply for the patient even if the device is accidentally positioned between two settings.
Control knob with large wings facilitating the grip and including a twin display of the selected flowrate.
Control knob with a wide transparent window to be able to read the selected flowrate as well as the previous and the next ones.
Rotating direction: counterclockwise.
Supplied in standard with a Stop system preventing the medical staff from switching from 0 to the maximum flow and conversely.
FLUSH system in option to deliver a brief and immediate gas flow of 30 l/min for specific applications.
Double filtration: filters at the inlet and at the outlet for optimal safety of both the patient and the device.
Metal parts made of nickel–plated brass.
Unit serial number engraved on each flowmeter body ensuring its identification and its traceability.

DEBSON Catalogue

DEBSON Catalogue

AVAILABLE VESIONS:
Gases: O2, medical Air
Flowrates:
1 l/min, 5 l/min, 15 l/min, 25 l/min, 50 l/min
Single or twin version
With or without FLUSH system
With or without Stop system
Standards: AFNOR (French standard), BS (British standard), DIN (German standard), US OHMEDA (American standard), UNI (Italian standard), NORDIC (Scandinavian standard), CARBUROS METALICOS (Spanish standard), DISS (American standard), Czech standard and Korean/Japanese standard. Contact us for other standard.

Pressure regulators - DETREG TM

The DETREG pressure regulator, connected to an Oxygen or medical Air cylinder, is used to regulate the gas pressure by supplying the operating outlet with a controlled and stable pressure below its supply pressure. The pressure of the compressed gas cylinder can be read on the pressure gauge of the device. Only equipped with a quick-release connector, it enables to supply a ventilator or any other medical device with gas. Two connection systems to the gas cylinder are available: – bullnose fitting: for large cylinders (> 4 litres in water or 0.8 m3) – yoke pin-index fitting: universal system for small cylinders (< 4 litres in water or 0.8 m3).

SPECIFTICATIONS:
Supply pressure: 200 bar
Outlet pressure: 4.5 bar
Piston type pressure regulator for a great reliability.
Single stage pressure regulator.
Integrated relief valve protected by the body of the pressure regulator thus ensuring its inviolability and its reliability.
Pressure gauge protected against shocks thanks to a plastic bumper.
Filter at the inlet to prevent the risks linked to high pressure.
Unit serial number engraved on the body of each pressure regulator ensuring its identification and traceability.
Device to be serviced every 5 years.

AVAILABLE VESIONS:
Gases: O2, medical Air, N2O
Connection systems and standards:
– Bullnose fitting:
O2: AFNOR (French standard), BS (British standard), DIN (German standard)
Medical Air: AFNOR (French standard), DIN (German standard)
N2O: AFNOR (French standard)
Contact us for other standard.
– Yoke pin-index fitting (O2 only): universal system

Pressure regulators - REGFLOW TM

The REGFLOW pressure regulator, connected to an Oxygen or medical Air cylinder, is used to regulate the gas pressure by supplying the operating outlet with a controlled and stable pressure below its supply pressure. The pressure of the compressed gas cylinder can be read on the pressure gauge of the device. Combined with an RTM3 flowmeter with floating ball, the REGFLOW pressure regulator enables to adjust and measure the flow of a gas that is to be delivered to patients through the respiratory tract from a gas cylinder. Fitted with a quick-release connector it also enables to supply a ventilator or any other medical device with gas. Two connection systems to the gas cylinder are available: Bullnose fitting: for large cylinders (> 4 litres in water or 0.8 m3), Yoke pin-index fitting: universal system for small cylinders (< 4 litres in water or 0.8 m3).

SPECIFTICATIONS:
Supply pressure: 200 bar
Outlet pressure: 4.5 bar
Piston type pressure regulator for a great reliability.
Single stage pressure regulator.
Integrated relief valve protected by the body of the pressure regulator thus ensuring its inviolability and its reliability.
Pressure gauge protected against shocks thanks to a plastic bumper.
Filter at the inlet to prevent the risks linked to high pressure.
Unit serial number engraved on the body of each pressure regulator ensuring its identification and traceability.
Device to be serviced every 5 years.

AVAILABLE VESIONS:
Gases: O2, (Also available in medical Air for AFNOR, DIN and NORDIC standards)
Flowrates:
1.5 l/min (paediatric) – 5 l/min – 15 l/min – 30 l/min
With or without quick-release connector
With or without VENTURI TM ejector (OXAP)
Connexions system and standards:
– Bullnose fitting: AFNOR (French standard), BS (British standard), DIN (German standard), US OHMEDA (American standard), UNI (Italian standard), NORDIC (Scandinavian standard). Contact us for other standard.
– Yoke pin-index fitting: universal system

Pressure regulators - REGSON TM2

The REGSON 2 pressure regulator, connected to an Oxygen or medical Air cylinder, is used to regulate the gas pressure by supplying the operating outlet with a controlled and stable pressure below its supply pressure. The pressure of the compressed gas cylinder can be read on the pressure gauge of the device. Combined with a DEBSON 2 flowmeter with pre-adjusted flowrates, the REGSON 2 pressure regulator enables to adjust and measure the flow of a gas that is to be delivered to patients through the respiratory tract from a gas cylinder. Fitted with a quick-release connector it also enables to supply a ventilator or any other medical device with gas. Two connection systems to the gas cylinder are available: bullnose fitting: for large cylinders (> 4 litres in water or 0.8 m3), yoke pin-index fitting: universal system for small cylinders (< 4 litres in water or 0.8 m3).

SPECIFTICATIONS:
Supply pressure: 200 bar
Outlet pressure: 4.5 bar
Piston type pressure regulator for a great reliability.
Single stage pressure regulator.
Integrated relief valve protected by the body of the pressure regulator thus ensuring its inviolability and its reliability.
Pressure gauge protected against shocks thanks to a plastic bumper.
Filter at the inlet to prevent the risks linked to high pressure.
It can be used in any orientation for a perfect adaptation to the medical needs especially for emergency.
Flow control knob equipped with a ratchet mechanism avoiding accidental flowrate change.
Presence of a gas flow between two positions ensuring the gas supply for the patient even if the device is accidentally positioned between two settings.
Control knob with large wings facilitating the grip and including a twin display of the selected flowrate.
Control knob with a wide transparent window to be able to read the selected flowrate as well as the previous and the next ones.
Rotating direction: counterclockwise.
Supplied in standard with a Stop system preventing the medical staff from switching from 0 to maximum flow and conversely.
Unit serial number engraved on the body of each pressure regulator ensuring its identification and traceability.
Device to be serviced every 5 years.

AVAILABLE VESIONS:
Gases: O2, (Also available in medical Air for AFNOR, DIN and NORDIC standards)
Flowrates:
1 l/min (paediatric) – 5 l/min – 15 l/min – 25 l/min – 50 l/min
With or without quick-release connector
With or without Stop system
With or without VENTURI TM ejector (OXAP)
Connection systems and standards:
– Bullnose fitting: AFNOR (French standard), BS (British standard), DIN (German standard), US OHMEDA (American standard), UNI (Italian standard), NORDIC (Scandinavian standard). Contact us for other standard.
– Yoke pin-index fitting: universal system

TM CE

TM CE

TM Catalogue REGFLOW

TM Catalogue REGFLOW