ICONIC-IS410

USER INTERFACE
High bright vacuum fluorescent display (VFD) , 256 x 64 resolution
Interactive menu on display
Cylinder pressure monitoring
Intelligent Alarm System
Argon Plasma Coagulation (Continuous Output)
Argon Plasma Coagulation (Pulsed Output)
Argon Cut
Bipolar Cut
Bipolar Coagulation (Auto-Start Bipolar & Manual Bipolar)
Monopolar Cut (Pure)
Monopolar Cut (Blend1)
Monopolar Cut (Blend2)
Monopolar Cut (Blend3)
Monopolar Coagulation (Swift)
Monopolar Coagulation (Forced)
Monopolar Coagulation (Spray)
Monopolar Coagulation (Soft)
Monopolar TUR Mode
Bipolar TUR Mode (Optional)
Automatic Self Checking (Spotting the system’s internal problems)
Permanent HF Electrosurgical Leakage current monitoring
Auto Stop Mode for Optimum tissue Coagulation (Preventing tissue Carbonization)
Permits two surgeons to coagulate at the same time independently in Spray Mode
Possibility of connecting independent Monopolar & Bipolar foot switches
75 Programmable memory locations
Special capability for IVF Surgery

Main Voltage: 220Vac + 10%, 50Hz or 110Vac + 10%, 50~60Hz

Maximum Power Consumption: 800V.A

Protection Class: Class I

Type of Output: CF

Weight: 8 kg

Dimensions (W.H.D): 40 x 17 x 44 cm

ICONIC-IS410S

Argon Plasma Coagulation (Continuous Output)
Argon Plasma Coagulation (Pulsed Output)
Argon Cut
Vessel Sealing (Seal 1) – Permanent sealing up to 7mm
Vessel Sealing (Seal 2) – Permanent sealing up to 7mm
Bipolar Cut
Bipolar Coagulation (Auto-Start Bipolar & Manual Bipolar)
Monopolar Cut (Pure)
Monopolar Cut (Blend1)
Monopolar Cut (Blend2)
Monopolar Cut (Blend3)
Monopolar Coagulation (Swift)
Monopolar Coagulation (Forced)
Monopolar Coagulation (Spray)
Monopolar Coagulation (Soft)
TUR Mode
Automatic Self Checking (Spotting the system’s internal problems)
Permanent HF Leakage current monitoring
Auto Stop Mode for Optimum tissue Coagulation (Preventing tissue Carbonization)
Utilizing a microprocessor system to control the current in vessel sealing, based on
measuring the impedance of the tissue
Permits two surgeons to coagulate at the same time independently in Spray Mode
Possibility of connecting both Monopolar & Bipolar foot switches independently
75 Programmable memory locations

Main Voltage: 220Vac + 10%, 50Hz or 110Vac + 10%, 50~60Hz
Maximum Power Consumption: 800V.A
Protection Class: Class I
Type of Output: CF
Weight: 8 kg
Dimensions (W.H.D): 40 x 17 x 44 cm